← RF Circuit Design
RF Circuit Design · Lab 3

VNA Calibration & L-Match

E157 Lab 3 · Fall 2026

Calibrating a vector network analyzer, then designing and hand-soldering an L-match from 270 Ω to 50 Ω at 100 MHz, checking the Smith chart after every part. Measured Q of 2.77 against 2.34 in theory.

  • VNA
  • Smith chart
  • Impedance matching
  • LTspice
  • MATLAB
  • SMD soldering
Finished L-match on the test board, with its measured and simulated Smith chart

Goal: match a 270 Ω load to a 50 Ω line at 100 MHz with an L-network, built component by component on a surface-mount test board.

Calibrating the VNA

Before calibration the VNA measures everything between its internal port and the load, including a meter of coax. That cable adds phase that grows with frequency, so a plain short circuit sweeps around the edge of the Smith chart instead of sitting at one point. Cable loss also pulls the magnitude below 1, and more so at higher frequency because of skin effect and dielectric loss. My measurement, LTspice simulation and hand analysis all agreed once I used the lab cable’s velocity factor of 0.66.

Uncalibrated: a 1 m cable with a short circuit, measured against LTspice and theory
Uncalibrated: a 1 m cable with a short circuit, measured against LTspice and theory
Uncalibrated reflection phase wrapping across 70–130 MHz
Uncalibrated reflection phase wrapping across 70–130 MHz

An open/short/load calibration solves for the error terms at every frequency point. After it, the short collapses to Γ = −1, the open to +1 and the 50 Ω load to the center. Changing the span to 90–110 MHz without recalibrating smeared the points out again slightly, a good reminder that a calibration only holds for the frequencies it was taken at.

Calibrated: the same short now sits at a single point, Γ = −1
Calibrated: the same short now sits at a single point, Γ = −1

Building the match one part at a time

My 270 Ω load was a 330 Ω and a 1.5 kΩ resistor in parallel. Its measured reflection at 100 MHz pointed to about 257 Ω instead, so I redesigned around the measured value rather than the nominal one.

I soldered the shunt inductor first and measured again. The closest part to my calculated 204 nH was 220 nH, which put the load at 57.7 + j107 Ω. From that measured point I recalculated the series capacitor, C = 1 / (2π · 107 Ω · 100 MHz) ≈ 14.9 pF, and used 15 pF. Checking the Smith chart after every part is how you get a good match from hand-assembled boards.

After the first part: the 220 nH shunt inductor moves the load up the chart
After the first part: the 220 nH shunt inductor moves the load up the chart

Results

The best match landed at 96.4 MHz. Using a |Γ| = 1/3 bandwidth from 82.9 to 117.7 MHz, the measured Q was 2.77, against 2.34 from my model. I traced the 15% difference to part tolerances, the inductance of the 0 Ω jumpers, and some unmodeled parasitic capacitance: the low band edge matched exactly, but the high edge came in early, which is what extra capacitance would do.

Measured |Γ| vs. frequency with the markers used to compute Q
Measured |Γ| vs. frequency with the markers used to compute Q
← RF Circuit Design